PVC 3 & 4 Core Round Submersible Pump Cable For South African Markets
Construction
Conductor
High purity electrolytic grade bright annealed flexible bunched bare,
copper conductor according to international standards like IS 8130,
BS 6360, IEC 228 & VDE 0295.
Insulation
Specially developed dielectric grade PVC Compound impervious to
water, oils, grease etc.
Sheath
Sheathing by High abrasion resistant tough & flexible PVC Compound
Standards
IS 694, BS 6500, IEC 60227, CEI 20-20, VDE 0281, SABS 1574, AS 3191,
AS/NZS 5000.1, HD 21.1, NF C 32-201, French Standard 32-102-16
Working Voltage Uo/U
450/ 750 V, 600/ 1000 V, 650/1100 V
Test Voltage
3000 V
Temperature range
-150C to 700 C
Core colors
(For South African Markets)
3 core
Red ,Yellow, Blue
4 core
Red ,Yellow, Blue, Green
Sheath color 3:
Blue
Sheath color 4:
Green
PVC 3 core Round Submersible Cable
Area (nom)
sq.mm
No./ size of wire
no./mm
Insulation thickness (nom.)
mm
Sheath thickness (nom.)
mm
Overall dimensio ns (approx.)
Mm
Conductor resistance at 20° C (max.)
ohm/km
Current carrying capacity at 40° C
amps.
3 x 1.5
22/.3
0.6
1.6
9.7
12.1
14
3 x 2.5
36/.3
0.7
1.6
10.7
7.41
18
3 x 4
56/.3
0.8
1.8
12.8
4.95
26
3 x 6
84/.3
0.8
1.8
14.4
3.3
31
3 x 10
140/.3
1
1.8
17.4
1.91
42
3 x 16
226/.3
1
2
21.2
1.21
57
3 x 25
354/.3
1.2
2.4
25.4
0.78
72
3 x 35
495/.3
1.2
2.6
29.1
0.554
90
3 x 50
703/.3
1.4
3.1
33.5
0.386
115
3 x 70
360/.5
1.4
3.2
39.1
0.272
143
3 x 95
475/.5
1.6
3.5
45.2
0.206
165
PVC 4 core Round Submerisble Cable
Area (nom)
sq.mm
Nos./ size of wire no./mm
Insulation thickness (nom.) mm
Sheath thickness (nom.) mm
Overall dimensions (approx.) mm
Conductor resistance at 20° C (max.) ohm/km
Current carrying capacity at 40° C amps.
4 x 1.5
22/.3
0.6
1.6
10.5
12.1
14
4 x 2.5
36/.3
0.7
1.6
11.7
7.41
18
4 x 4
56/.3
0.8
1.8
14
4.95
26
4 x 6
84/.3
0.8
1.8
15.7
3.3
31
4 x 10
140/.3
1
1.8
19.1
1.91
42
4 x 16
226/.3
1
2
22.7
1.21
57
4 x 25
354/.3
1.2
2.6
29.4
0.78
72
4 x 35
495/.3
1.2
2.6
31.6
0.554
90
4 x 50
703/.3
1.4
3.1
37
0.386
115
4 x 70
360/.5
1.4
3.2
43.2
0.272
143
4 x 95
475/.5
1.6
3.5
50
0.206
165
Note:
Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-228 & VDE-0295.