Drinking Water Submersible Pump Cable: Round |
|
- ROHS (lead free) for drinking water submersible pump
|
| Construction |
- Conductor
High purity electrolytic grade bright annealed flexible bunched bare,
copper conductor according to international standards like IS 8130,
BS 6360, IEC 228 & VDE 0295.
- Insulation
Oil & Water Resistant Thermoplastic Rubber Compound (TPE/TPR)
- Sheath
Heavy Duty Thermoplastic Rubber Compound (TPE/TPR).
|
| Standards |
- BS 6007, IEC 60245, CEI 20-19, VDE 0282, AS 3191,
AS/NZS 5000.1, HD 22.1, , NF C 32-201, French Standard 32-102-16
|
| Working Voltage Uo/U |
- 450/ 750 V, 600/ 1000 V, 650/1100 V
|
| Test Voltage |
|
|
| Temperature range |
|
|
|
| Core colors |
(For Asian, African Markets) |
(For European Markets) |
| 3 core |
Red ,Yellow, Blue |
Black, Blue, Brown |
| 4 core |
Red ,Yellow, Blue, Green |
Black, Blue, Brown, Green |
| Sheath color: |
Blue |
Blue |
| |
 |
 |
| |
 |
 |
|
Rubber 3 Core Double Sheathed Round Submersible Pump Cable |
Area (nom)
sq.mm
|
No./
size of
wire
no./mm |
Insulation
thickness
(nom.)
mm |
Sheath
thickness (nom.)
mm |
Overall
dimensio
ns
(approx.)
Mm |
Conductor
resistance
at 20° C
(max.)
ohm/km
|
Current
carrying
capacity at
40° C
amps.
|
| 3 x 1.5 |
22/.3 |
0.6 |
1.6 |
9.7 |
12.1 |
14 |
| 3 x 2.5 |
36/.3 |
0.7 |
1.6 |
10.7 |
7.41 |
18 |
| 3 x 4 |
56/.3 |
0.8 |
1.8 |
12.8 |
4.95 |
26 |
| 3 x 6 |
84/.3 |
0.8 |
1.8 |
14.4 |
3.3 |
31 |
| 3 x 10 |
140/.3 |
1 |
1.8 |
17.4 |
1.91 |
42 |
| 3 x 16 |
226/.3 |
1 |
2 |
21.2 |
1.21 |
57 |
| 3 x 25 |
354/.3 |
1.2 |
2.4 |
25.4 |
0.78 |
72 |
| 3 x 35 |
495/.3 |
1.2 |
2.6 |
29.1 |
0.554 |
90 |
| 3 x 50 |
703/.3 |
1.4 |
3.1 |
33.5 |
0.386 |
115 |
| 3 x 70 |
360/.5 |
1.4 |
3.2 |
39.1 |
0.272 |
143 |
| 3 x 95 |
475/.5 |
1.6 |
3.5 |
45.2 |
0.206 |
165 |
|
Rubber 4 Core Double Sheathed Round Submersible Pump Cable
|
Area (nom)
sq.mm
|
Nos./
size of
wire
no./mm
|
Insulation
thickness
(nom.)
mm
|
Sheath
thickness
(nom.)
mm
|
Overall
dimensions
(approx.)
mm
|
Conductor
resistance
at 20° C
(max.)
ohm/km |
Current
carrying
capacity at
40° C
amps. |
| 4 x 1.5 |
22/.3 |
0.6 |
1.6 |
10.5 |
12.1 |
14 |
| 4 x 2.5 |
36/.3 |
0.7 |
1.6 |
11.7 |
7.41 |
18 |
| 4 x 4 |
56/.3 |
0.8 |
1.8 |
14 |
4.95 |
26 |
| 4 x 6 |
84/.3 |
0.8 |
1.8 |
15.7 |
3.3 |
31 |
| 4 x 10 |
140/.3 |
1 |
1.8 |
19.1 |
1.91 |
42 |
| 4 x 16 |
226/.3 |
1 |
2 |
22.7 |
1.21 |
57 |
| 4 x 25 |
354/.3 |
1.2 |
2.6 |
29.4 |
0.78 |
72 |
| 4 x 35 |
495/.3 |
1.2 |
2.6 |
31.6 |
0.554 |
90 |
| 4 x 50 |
703/.3 |
1.4 |
3.1 |
37 |
0.386 |
115 |
| 4 x 70 |
360/.5 |
1.4 |
3.2 |
43.2 |
0.272 |
143 |
| 4 x 95 |
475/.5 |
1.6 |
3.5 |
50 |
0.206 |
165 |
|
| |
| Note: |
| Insulation thickness, Sheath thickness and overall dimensions are nominal values. The number of wires is approximate and strand diameter is nominal; they shall be such as to satisfy the requirements of conductor resistance as per IS 8130/1984, BS-6360, IEC-60228 & VDE-0295. |
| |
|
|
|